top of page
= Quality
Testing Capabilities
-
Daily titration testing of all tanks.
-
Destructive and adhesion testing conducted every shift to ASTM standards.
-
In-House Hull Cell testing occurs on plating solution.
-
3rd party salt spray testing by an approved A2LA accredited lab is conducted at regular intervals for process monitoring.
Holly Plating has plated product that conforms with the following Zinc Electroplating Specifications:
ASTM
ATTM B633
CAT
1EO397E
Chrysler
PS-79
PS- 1207
PS-Plating
Ford
WSS-M21P17-B1
WSDM-MIP85-A
WSS-M1P85-B
GM
GMW3044
GM4345
Honda
HES D2003
John Deere
JDM F23
JDS 117
MTD
100015
Toyota
TSH6524G
bottom of page